Technical Data
CompareContinuous / Liquids
| Measuring Principle | Hydrostatic |
| Characteristic / Application | Compact pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant and climatic-proofed |
| Specialities | Diagnostic functions |
| Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC (Non Ex) |
| Accuracy | Standard 0.1% Optional 0.075% |
| Long term stability | 0.05 % of URL/year |
| Ambient temperature | -40°C...+85°C (-40°F...+185°F) |
| Process temperature | -10°C...+100°C (+14°F...+212°F) |
| Process pressure / max. overpressure limit | 40 bar (600 psi) |
| Pressure measuring range | 100 mbar...10 bar (1.5 psi...150 psi) |
| Main wetted parts | Alloy C 316L |
| Process connection | Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
| Max. measurement distance | 100 m (328 ft) H2O |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC |
| Safety approvals | SIL |
| Design approvals | EN10204-3.1 NACE MR0175, MR0103 |
| Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
| Marine approval | GL/ DNV |
| Drinking water approvals | NSF |
| Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing |
| Application limits | Measuring cell: Contite, condensate-proof, watertight, metal welded If pressurized, possibly use differential pressure measurement with two pressure transmitters. Observe ratio head pressure : hydrostatic pressure |
Pressure
| Measuring Principle | Hydrostatic pressure |
| Characteristic | Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell: Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Compact version |
| Supply voltage | 4...20 mA HART 10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex) |
| Reference Accuracy | Standard 0.1% Optional 0.075% |
| Long term stability | 0.05 % of URL/year |
| Process temperature | -10°C...100°C (14°F...212°F) |
| Ambient temperature | -40°C...85°C (-40°F...185°F) |
| Measuring cell | 100 mbar...10 bar (1.5 psi...150 psi) |
| Smallest calibratable span | 25 mbar (3.63 psi) |
| Vacuum resistance | 0 mbar abs. |
| Max. overpressure limit | 40 bar (600 psi) |
| Process connection | Thread: G1 1/2, MNPT1/2 Flange: DN40...DN100, ASME 1 1/2"...4", JIS 10K |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD |
| Material process membrane | 316L, AlloyC, Gold-Rhodium |
| Material gasket | None, measuring cell welded |
| Fill fluid | Inert oil, Synthetic oil |
| Material housing | 316L, Die-cast aluminum |
| Communication | 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus |
| Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex |
| Safety approvals | SIL |
| Design approvals | EN10204-3.1 NACE MR0175 MR0103 |
| Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
| Marine approvals | GL, DNV |
| Drinking water approvals | NSF |
| Specialities | Gold-rhodium coated membrane |
The Deltapilot FMB70 uses a condensation-resistant CONTITE measuring cell and a dual-compartment housing. It is mainly used in the process and hygienic industries to measure the level of liquid or paste media in open or closed vessels, and the measurement is unaffected by foam. The built-in HistoROM data module facilitates management of process and device parameters. The design complies with IEC 61508 and meets SIL3 functional safety requirements.
Benefits
Excellent repeatability and long-term stability
Hermetically sealed CONTITE measuring cell: condensation-resistant and climate-protected; high reference accuracy: ±0.1 %, optional ±0.075 %; minimal temperature effect
For process pressure monitoring up to SIL3, in accordance with IEC 61508, certified by TÜV SÜD
HistoROM®/M-DAT memory module
Function monitoring of the measuring element and the electronics
Continuous modular measurement of differential pressure, static pressure and pressure (Deltabar S, Deltapilot S, Cerabar S), e.g. replaceable display, universal electronics
Simple commissioning without tools
Application areas
Hydrostatic sensors can be used for the following measurements:
Static pressure measurement of liquids and pastes in the process industry, process measurement, pharmaceutical and food industries
Measurement of liquid level, volume or mass
E+H product model configurator
Please enter the product model to configure
Product comparison
Please enter the product models to be compared in the input boxes below; up to three products can be compared
Technical information
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: public information from the Endress+Hauser website
Related Models
| Model | Name |
|---|---|
| FMB70-ABR1F121GCAA | 静压式液位计 |
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Static Pressure Measurement Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Static Pressure Measurement Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Static Pressure Measurement Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Static Pressure Measurement Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.