Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

FMB52 static pressure level gauge

FMB52 static pressure level gauge

Deltapilot M FMB52

Configurable Models 2 models
The pressure sensor uses CONTITE components for static pressure level measurement
Compare

Continuous / Liquids

Measuring Principle Hydrostatic
Characteristic / Application Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant and climatic-proofed
Cable version
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
diagnostic functions
Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC (Non Ex)
Accuracy Standard 0.2%
Optional 0.1%
Long term stability 0.05 % of URL/year
Ambient temperature -40°C...85°C
(-40°F...185°F)
Process temperature PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F
Process pressure / max. overpressure limit 40 bar (600 psi)
Pressure measuring range 100 mbar...10 bar
(1.5 psi...150 psi)
Main wetted parts Alloy C
316L
Cable (PE/FEP)  
optional coating AuPt
optional coating AuRh
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Max. measurement distance 100 m (328 ft) H2O
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals Overfill protection WHG
SIL
Design approvals EN10204-3.1
NACE MR0175
Marine approval GL/ ABS/ LR/ BV/ DNV
Drinking water approvals KTW/ NSF/ ACS
Options Separate housing
Initial device settings
Overvoltage protection
Application limits If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
Observe ratio head pressure : hydrostatic pressure
In case of an open tank or shaft use FMB53 with mounting clamp.

Pressure

Measuring Principle Hydrostatic pressure
Characteristic Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Cable version
Supply voltage 4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)
Reference Accuracy Standard 0.2%
Optional 0.1%
Long term stability 0.05 % of URL/year
Process temperature PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F
Ambient temperature -40°C...85°C
(-40°F...185°F)
Measuring cell 100 mbar...10 bar
(1.5 psi...150 psi)
Smallest calibratable span 10 mbar (1.45 psi)
Vacuum resistance 0 mbar abs.
Max. Turn down 100:1
Max. overpressure limit 40 bar (600 psi)
Process connection Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Material process membrane 316L, AlloyC,
Gold-Rhodium
PE, FEP
Material gasket Viton, EPDM, Kalrez, none
Fill fluid Inert oil,
Synthetic oil
Material housing 316L, Die-cast aluminum
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals Overfill protection WHG
SIL
Design approvals EN10204-3.1
NACE MR0175
Marine approvals GL/ ABS/ LR/ BV/ DNV
Drinking water approvals KTW/ NSF/ ACS
Specialities Modularity to differential pressure and process pressure devices (replacable display, universal electronics)
Diagnostic functions

The Deltapilot FMB52 cable sensor uses a CONTITE measuring cell with a fixed process connection. It is mainly used in the process and environmental industries and measures the level of liquid or paste media in open or closed vessels, unaffected by foam. The design complies with IEC 61508 and meets SIL2 functional safety requirements.

Benefits:

  • Excellent repeatability and long-term stability

  • Turndown: 100:1

  • Hermetically sealed CONTITE measuring cell: condensation-resistant and climate-protected; high reference accuracy: ±0.2 %, optional ±0.1 %; minimal temperature effect

  • Point-to-point module measuring differential pressure, static pressure and pressure (Deltabar M - Deltapilot M - Cerabar M), e.g. replaceable display, universal electronics

  • Simple commissioning without tools

Application areas:

Hydrostatic sensors can be used for the following measurements:;

  • Static pressure measurement of liquids and pastes in the process industry, process measurement, pharmaceutical and food industries

  • Measurement of liquid level, volume or mass

  •  

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: public information from the Endress+Hauser website

Model Name
FMB52-AA21JA1FGA35GGJB2UHC 静压液位计
FMB52-AA22IA1FGA15GGJB3U 静压液位计
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Static Pressure Measurement Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Static Pressure Measurement Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Static Pressure Measurement Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Static Pressure Measurement Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Static Pressure Measurement.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Static Pressure Measurement for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.