Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

质量流量计 8E3B

质量流量计  8E3B

质量流量计 8E3B

Configurable Models 15 models
The robust Promass E has a long-standing reputation as a reliable solution accurately measuring liquids and gases in a wide range of standard applications in various industries. With its compact transmitter Promass E 300 offers high flexibility in terms of operation and system integration: access from one side, remote display, improved connectivity options. Heartbeat Technology ensures measurement reliability and enables extension of recalibration cycles.
Compare

Density

Measuring Principle Coriolis
Product Headline Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.
Accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.

Density/Concentration

Measuring Principle Coriolis
Product headline Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.
Accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6615 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +150 °C (–40 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated; stainless steel for hygenic transmitter design
Degree of protection Standard: IP66/67, Type 4X enclosure
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available"
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Gas

Measuring Principle Coriolis
Product headline Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.
Accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6615 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +150 °C (–40 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated; stainless steel for hygenic transmitter design
Degree of protection Standard: IP66/67, Type 4X enclosure
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available"
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Liquids

Measuring Principle Coriolis
Product headline Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.
Accurate measurement of liquids and gases for a wide range of standard applications.
Sensor features Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Process pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.
Nominal diameter range DN 8 to 80 (⅜ to 3")
Wetted materials Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 180 000 kg/h (0 to 6615 lb/min)
Max. process pressure PN 100, Class 600, 63K
Medium temperature range –40 to +150 °C (–40 to +302 °F)
Ambient temperature range Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated; stainless steel for hygenic transmitter design
Degree of protection Standard: IP66/67, Type 4X enclosure
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available"
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
Product safety CE, C-tick, EAC marking
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, EHEDG, cGMP

Steam

Measuring Principle Coriolis
Product headline Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.
Accurate measurement of liquids and gases for a wide range of standard applications.
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval

The Promass E is robust and is an economical solution for long-term use in high-precision liquid and gas measurement in various standard applications across different industries. Combined with the compact transmitter, the Promass E 300 offers flexible operation and easy system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology ensures compliance at all times and guarantees process safety.

Benefits
Economical: versatile instrument; preferred alternative to conventional volumetric flowmeters
Fewer process measuring points: multivariable measurement (flow, density, temperature)
Space-saving installation: no inlet/outlet straight run requirement
Complete view of process and diagnostic information: various user-configurable input/output combinations and fieldbuses
Reduced complexity and diversity: user-configurable input/output functions
Integrated verification: built-in Heartbeat Technology

Applications
The measuring principle is unaffected by the physical properties of the fluid (e.g. viscosity and density).
High-precision measurement of liquids and gases in standard applications, with broad applicability.

Device features
Compact dual measuring tube sensor
Medium temperature: max. +150 °C (+302 °F)
Process pressure: max. 100 bar (1450 psi)
Compact dual-compartment housing with up to 3 inputs/outputs
Backlit display, touch key operation and WLAN access
Remote display unit available

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measurement principle video

Source: Endress+Hauserpublic information from the website

Model Name
8E3B08-AAIBAEAFAASAD2SHA1+AK 8E3B08-AAIBAEAFAASAD2SHA1+AK
8E3B08-BBDBAEAFAASAD2SHA1+AK 8E3B08-BBDBAEAFAASAD2SHA1+AK
8E3B15-AAIBAEAFAASAD2SHA1+AK 8E3B15-AAIBAEAFAASAD2SHA1+AK
8E3B15-BBDBAEAFAASAD2SHA1+AK 8E3B15-BBDBAEAFAASAD2SHA1+AK
8E3B25-AAIBAEAFAASAD2SHA1+AK 8E3B25-AAIBAEAFAASAD2SHA1+AK
8E3B25-BBDBAEAFAASAD2SHA1+AK 8E3B25-BBDBAEAFAASAD2SHA1+AK
8E3B40-AAIBAEAFAASAD2SHA1+AK 8E3B40-AAIBAEAFAASAD2SHA1+AK
8E3B40-BBDBAEAFAASAD2SHA1+AK 8E3B40-BBDBAEAFAASAD2SHA1+AK
8E3B40-BDEBAEAFADSAAASAA1 8E3B40-BDEBAEAFADSAAASAA1
8E3B50-AAIBAEAFAASAD2SHA1+AK 8E3B50-AAIBAEAFAASAD2SHA1+AK
8E3B50-BBDBAEAFAASAD2SHA1+AK 8E3B50-BBDBAEAFAASAD2SHA1+AK
8E3B50-BSIBAEAFAASAD2SHA2+AK 8E3B50-BSIBAEAFAASAD2SHA2+AK
8E3B80-AAIBAAAFAASAD2SHA1+AK 8E3B80-AAIBAAAFAASAD2SHA1+AK
8E3B80-AAIBAEAFAASAD2SHA1+AK 8E3B80-AAIBAEAFAASAD2SHA1+AK
8E3B80-BBDBAEAFAASAD2SHA1+AK 8E3B80-BBDBAEAFAASAD2SHA1+AK
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Mass Flow Meter Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Mass Flow Meter Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Mass Flow Meter Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Mass Flow Meter Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.