Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

8A3C 质量流量计

8A3C 质量流量计

质量流量计

Configurable Models 7 models
Promass A is ideal for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow rates and high pressure. With its compact transmitter Promass A 300 offers high flexibility in terms of operation and system integration: access from one side, remote display, improved connectivity options. Heartbeat Technology ensures measurement reliability and compliant verification.
Compare

Density/Concentration

Measuring Principle Coriolis
Product headline Accurate single-tube flowmeter for lowest flow rates with a compact, easily accessible transmitter.
Suitable for applications with smallest flow quantities in all industries.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Degree of protection Compact version: IP66/67, type 4X enclosure.
External WLAN antenna: IP67
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Gas

Measuring Principle Coriolis
Product headline Accurate single-tube flowmeter for lowest flow rates with a compact, easily accessible transmitter.
Suitable for applications with smallest flow quantities in all industries.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Degree of protection Compact version: IP66/67, type 4X enclosure.
External WLAN antenna: IP67
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

Liquids

Measuring Principle Coriolis
Product headline Accurate single-tube flowmeter for lowest flow rates with a compact, easily accessible transmitter.
Suitable for applications with smallest flow quantities in all industries.
Sensor features Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging.
Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
Wetted materials Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Measured variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density
Max. measurement error Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
Measuring range 0 to 450 kg/h (0 to 16.54 lb/min)
Max. process pressure 430.9 bar (6250 psi)
Medium temperature range -50 to 205 °C (-58 to 401 °F)
Ambient temperature range -40 to 60 °C (-40 to +140 °F)
Sensor housing material Stainless steel, 1.4404 (316L)
Transmitter housing material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Degree of protection Compact version: IP66/67, type 4X enclosure.
External WLAN antenna: IP67
IP69
Display/Operation 4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Inputs Status input
4-20 mA input
Digital communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power supply DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, UK Ex
Product safety CE, C-TICK
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates 3-A, cGMP

The Promass A is the ideal choice for continuous process control under demanding conditions. The single-tube flowmeter with its unique self-draining function measures very small liquid and gas flows with high precision and can also measure under high pressure. Combined with the compact Promass A 300 transmitter, it offers flexible operation and convenient system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology ensures reliable measurement and verified compliance.

Advantages
Small installation space required: compact, lightweight sensor
Highest product quality: self-draining measuring tube design
Maximum process safety: resistant to corrosive ambient conditions and can measure in pipes that may become clogged internally
Complete access to process and diagnostic information: a wide range of user-configurable input/output combinations and fieldbuses
Reduced complexity and variability: user-configurable input/output functions
Self-verification: Heartbeat Technology

Application areas
Measuring principle unaffected by the physical properties of the fluid (e.g. viscosity or density)
Suitable for measuring very small flows in all industries

Instrument features
Nominal diameter: DN 1...4 (1/24...1/8")
Maximum process pressure: 430.9 bar (6250 psi)
Maximum medium temperature: +205 °C (+401 °F)
Compact dual-compartment housing with up to 3 inputs/outputs
Backlit display, touch control and WLAN access
Remote display unit available

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

Source:Endress+Hauserpublic information from the website

Model Name
8A3C01-AAIBADDFBASAHAWAA2+ABPR 8A3C01-AAIBADDFBASAHAWAA2+ABPR
8A3C01-AAIBAEAFAASAHAWAA1+AK 8A3C01-AAIBAEAFAASAHAWAA1+AK
8A3C01-BBDBAEAFAASAHAWAA1+AK 8A3C01-BBDBAEAFAASAHAWAA1+AK
8A3C02-AAIBAEAFAASAHAWAA1+AK 8A3C02-AAIBAEAFAASAHAWAA1+AK
8A3C02-BBDBAEAFAASAHAWAA1+AK 8A3C02-BBDBAEAFAASAHAWAA1+AK
8A3C04-AAIBAEAFAASAHAWAA1+AK 8A3C04-AAIBAEAFAASAHAWAA1+AK
8A3C04-BBDBAEAFAASAHAWAA1+AK 8A3C04-BBDBAEAFAASAHAWAA1+AK
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Mass Flow Meter Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Mass Flow Meter Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Mass Flow Meter Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Mass Flow Meter Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Mass Flow Meter.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Mass Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.