电磁流量计
Technical Data
CompareLiquids
| Measuring Principle | Electromagnetic |
| Product headline | High-temperature flowmeter for process applications with a compact, easily accessible transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures. |
| Sensor features | Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals. |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Liner made of PTFE or PFA. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
| Nominal diameter range | DN 15 to 600 (½ to 24") |
| Wetted materials | Liner: PFA; PTFE Electrodes: 1.4435 (F316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium |
| Measured variables | Volume flow, conductivity, mass flow |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec |
| Measuring range | 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) |
| Max. process pressure | PN 40, Class 300, 20K |
| Medium temperature range | Liner material PFA: –20 to +150 °C (–4 to +302 °F) Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F) Liner material PTFE: –40 to +130 °C (–40 to +266 °F) |
| Ambient temperature range | Flange material carbon steel: –10 to +60 °C (+14 to +140 °F) Flange material stainless steel: –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | DN 15 to 300 (½ to 12""): AlSi10Mg, coated DN 350 to 600 (14 to 24""): Carbon steel with protective varnish |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design |
| Degree of protection | Standard: IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | ACS, NSF 61, WRAS |
The E+H electromagnetic flowmeter 5P3B sensor is designed for high-temperature, corrosive media in chemical and process applications. Used with a compact transmitter, the Promag P 300 offers flexible operation and convenient system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology ensures compliance at all times and guarantees process safety.
Benefits
Wide range of applications: various wetted parts materials available
Energy-saving flow measurement: no flow restriction components, ensuring no pressure loss
Maintenance-free: no moving parts
Complete view of process and diagnostic information: various user-defined input/output combinations and fieldbuses available
Reduced complexity and variety: user-defined input/output functions
Built-in verification: integrated Heartbeat Technology
Application areas
Bidirectional measuring principle unaffected by pressure, density, temperature and viscosity
Specialized flowmeter for measuring high-temperature, corrosive media in chemical and process applications
Instrument features
Nominal diameter: max. DN 600 (24")
All common explosion protection (Ex) approvals
PTFE or PFA liner
Compact dual-compartment housing with up to 3 inputs/outputs
Backlit display, touch key control and WLAN access
Separate display unit available
E+H product model configurator
Please enter the product model to configure
Product comparison
Please enter the product models to be compared in the input boxes below; up to three products can be compared
Technical information
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Measuring principle video
Source: public information from the Endress+Hauser website
Related Models
| Model | Name |
|---|---|
| 5P3B15-AAIBAEAOAAED5S0AA2AB | 5P3B15-AAIBAEAOAAED5S0AA2AB |
| 5P3B1F-AAIBAEDFAAED3K0AA1 | 5P3B1F-AAIBAEDFAAED3K0AA1 |
| 5P3B1F-BBDBAEAFAAED5S0AA1ABDAJAJBLALKZ1 | 5P3B1F-BBDBAEAFAAED5S0AA1ABDAJAJBLALKZ1 |
| 5P3B1H-AAIBAEAFAAED5K0AA2 | 5P3B1H-AAIBAEAFAAED5K0AA2 |
| 5P3B40-BDDBAAAOADED5S2BA2+AKRAZ1 | 5P3B40-BDDBAAAOADED5S2BA2+AKRAZ1 |
| 5P3B50-BBDBADDFAAED5K1AA2+ABLKZ1 | 5P3B50-BBDBADDFAAED5K1AA2+ABLKZ1 |
| 5P3B50-BDDBAAAOADED5S2BA2+AKL9RAZ1 | 5P3B50-BDDBAAAOADED5S2BA2+AKL9RAZ1 |
| 5P3B65-AAIBAEDFAAAD3S0AA2AB | 5P3B65-AAIBAEDFAAAD3S0AA2AB |
| 5P3B80-AAIBAEAFAAAD5K8AA1 | 5P3B80-AAIBAEAFAAAD5K8AA1 |
| 5P3B80-BDECAAAFABAA1KGMA1AADAJAJBLKZ1 | 5P3B80-BDECAAAFABAA1KGMA1AADAJAJBLKZ1 |
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Electromagnetic Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Electromagnetic Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Electromagnetic Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Electromagnetic Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.