电磁流量计
Technical Data
CompareLiquids
| Measuring Principle | Electromagnetic |
| Product headline | Specialist for hygienic applications with a compact, easily accessible transmitter. Dedicated to demanding applications in the food and beverage as well as in life sciences industries. |
| Sensor features | Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG). |
| Transmitter features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Wetted materials CIP, SIP cleanable. Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. |
| Nominal diameter range | DN 2 to 150 (¹⁄₁₂ to 6") |
| Wetted materials | Liner: PFA Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone) Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum |
| Measured variables | Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity |
| Max. measurement error | Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s) Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s) |
| Measuring range | 0.06 dm³/min to 600 m³/h (0.015 gal/min to 2 650 gal/min) |
| Max. process pressure | PN 40, Class 150, 20K |
| Medium temperature range | –20 to +150 °C (–4 to +302 °F) |
| Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
| Sensor housing material | 1.4301 (304), corrosion resistant |
| Transmitter housing material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design |
| Degree of protection | IP66/67, type 4X enclosure IP69 |
| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
| Inputs | Status input 4-20 mA input |
| Digital communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Modbus TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
| Power supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
| Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC; JPN, UK Ex, KC |
| Product safety | CE, C-tick, EAC marking |
| Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
| Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
| Marine approvals and certificates | LR approval, DNV approval, ABS approval, BV approval |
| Pressure approvals and certificates | PED, CRN |
| Material certificates | 3.1 material |
| Hygienic approvals and certificates | Sanitary approval: EHEDG, 3-A, liner and seals acc. to FDA, cGMP |
The Promag H 300 5H3B sensor is suitable for the most demanding applications in the food & beverage and life sciences industries. The ultra-compact transmitter has the smallest housing in the industry yet delivers the most comprehensive performance and easy, seamless system integration, making the Promag H 300 the first choice for skid builders, system integrators and other equipment manufacturers. Heartbeat Technology ensures compliance and process safety at all times.
Benefits
Multivariable measurement of flow, temperature and conductivity
Flexible installation - various process connections complying with hygienic requirements
Energy-saving flow measurement - cross-section identical to the pipe, no pressure loss
Space-saving transmitter - small device, full functionality
Localized operation without additional hardware and software, saving time - integrated web server
Integrated verification - Heartbeat Technology
Maintenance-free – no moving parts
Application areas
Bidirectional measurement unaffected by pressure, density, temperature and viscosity
Suitable for demanding applications in the food & beverage and life sciences industries
Device features
Built-in temperature measurement
Sensor housing made of stainless steel (3-A, EHEDG)
Wetted parts materials withstand CIP and SIP cleaning
Rugged ultra-compact transmitter housing
High protection rating: IP69
With on-site display
E+H product model configurator
Please enter the product model to configure
Product comparison
Please enter the product models to be compared in the input boxes below; up to three products can be compared
Technical information
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: public information from the Endress+Hauser website
Related Models
| Model | Name |
|---|---|
| 5H3B02-AAIBAEAOAD00000AA1+AK | 5H3B02-AAIBAEAOAD00000AA1+AK |
| 5H3B40-AAIBAEAFBAHAAS0BA2 | 电磁流量计 |
| 5H3B65-AAIBADDGBAFDAS0AA2+ABLT | 5H3B65-AAIBADDGBAFDAS0AA2+ABLT |
| 5H3B65-AAIBAEBFAAFDAS0EA2 | 5H3B65-AAIBAEBFAAFDAS0EA2 |
| 5H3B80-AAIBABEFAAFDASGBA2ABCFJALPLTNB | 5H3B80-AAIBABEFAAFDASGBA2ABCFJALPLTNB |
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Electromagnetic Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Electromagnetic Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Electromagnetic Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Electromagnetic Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Electromagnetic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Electromagnetic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.