Meas. cable CYK10 Memosens
Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
Disinfection
| Measuring Principle | Free chlorine |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
ORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals. |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 ... 135 °C (-13 ... 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
pH
| Measuring Principle | Potentiometric |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Measuring range | High impedance cable not necessary |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Process pressure | max. 50 bar/725 psi at 135°C/275°F. |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
| Ingress protection | IP68 |
CYK10 ensures a completely waterproof connection between Memosens sensors and transmitters. Its inductive coupling guarantees galvanic isolation between the transmitter and the medium without corrosion. Fully safe signal transmission protects against moisture and potential interference.
Benefits
Completely waterproof connection (IP 68)
Corrosion-free connection
Galvanic isolation between transmitter and medium blocks potential interference
Application areas
The Memosens digital cable CYK10 can be used in Memosens systems to measure the following parameters:
pH/ORP
Dissolved oxygen (amperometric)
Conductivity
Reverse osmosis
Common models: CYK10-A101 10 m and CYK10-A051 5 m
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Measuring Principle Video
Source:Endress+Hauserwebsite public information
Related Models
| Model | Name |
|---|---|
| CYK10-A031 | PH电缆 |
| CYK10-A032 | PH电缆 |
| CYK10-A051 | PH电缆 |
| CYK10-A101 | PH电缆 |
| CYK10-A151 | PH电缆 |
| CYK10-A201 | PH电缆 |
| CYK10-A251 | PH电缆 |
| CYK10-A881 | PH电缆 |
| CYK10-E051 | PH电缆 |
| CYK10-E101 | PH电缆 |
| CYK10-G031 | PH电缆 |
| CYK10-G051 | PH电缆 |
| CYK10-G101 | PH电缆 |
| CYK10-G881 | PH电缆 |
| CYK10-J051 | PH电缆 |
| CYK10-J101 | PH电缆 |
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · pH Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of pH.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · pH Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of pH.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · pH Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of pH.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · pH Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of pH.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable pH for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserOrbisint CPS11D Memosens
Endress+HauserLiquisys M CPM223
Endress+HauserMemosens CPS11E
Endress+HauserOrbipac CPF81
Endress+HauserLiquisys M CPM253
Endress+HauserCeragel CPS71D Memosens
Endress+HauserOrbipac CPF81D Memosens
Endress+Hauser