PH电缆
Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
Disinfection
| Measuring Principle | Free chlorine |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
ORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals. |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter. |
| Characteristic | Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 ... 135 °C (-13 ... 277 °F) |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
pH
| Measuring Principle | Potentiometric |
| Application | Measuring cable for contactless, inductive, digital transmission of measurement signals |
| Installation | Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter |
| Characteristic | Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion |
| Measuring range | High impedance cable not necessary |
| Design | Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity |
| Material | Cable sheath: TPE Junction box: aluminum |
| Dimension | Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft) |
| Process temperature | -25 to 135 °C (-13 to 277 °F) |
| Process pressure | max. 50 bar/725 psi at 135°C/275°F. |
| Temperature sensor | For digital sensors with inductive plug-head with and without temperature sensor |
| Ex certification | ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex ic IIC |
| Ingress protection | IP68 |
CYK10 ensures a completely waterproof connection between Memosens sensors and transmitters. Its inductive coupling guarantees galvanic isolation between the transmitter and the medium without corrosion. Fully safe signal transmission protects against moisture and potential interference.
Benefits
Completely waterproof connection (IP 68)
Corrosion-free connection
Galvanic isolation between transmitter and medium blocks potential interference
Application areas
The Memosens digital cable CYK10 can be used in Memosens systems to measure the following parameters:
pH/ORP
Dissolved oxygen (amperometric)
Conductivity
Reverse osmosis
Common models: CYK10-A101 10 m and CYK10-A051 5 m
E+H Product Configurator
Please enter the product model to configure
Product Comparison
Please enter the product models to compare in the fields below. Up to three products can be compared
Technical Documentation
Technical Specifications
Documents/Manuals/Software
Accessories/Spare Parts
Measuring Principle Video
Source:Endress+Hauserwebsite public information
Related Models
| Model | Name |
|---|---|
| CYK10-A031 | PH电缆 |
| CYK10-A032 | PH电缆 |
| CYK10-A051 | PH电缆 |
| CYK10-A101 | PH电缆 |
| CYK10-A151 | PH电缆 |
| CYK10-A201 | PH电缆 |
| CYK10-A251 | PH电缆 |
| CYK10-A881 | PH电缆 |
| CYK10-E051 | PH电缆 |
| CYK10-E101 | PH电缆 |
| CYK10-G031 | PH电缆 |
| CYK10-G051 | PH电缆 |
| CYK10-G101 | PH电缆 |
| CYK10-G881 | PH电缆 |
| CYK10-J051 | PH电缆 |
| CYK10-J101 | PH电缆 |
Case Studies
市政污水处理污水处理厂 · PH应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · PH应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · PH应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · PH应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对PH的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的PH,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。