浊度传感器
Technical Data
CompareTotal Solids / Total Suspended Solids
| Measuring Principle | Four beam alternating light |
| Application | Wastewater, process water and primary water treatment applications. Turbidity and suspended solids measurement at all stages of the wastewater treatment process and at primary water treatment applications with medium to high turbidities. |
| Installation | Insitu (immersion in process or retractable holder), extractive with sample and flow cell |
| Design | 40 mm sensor, stainless steel |
| Dimension | 194 mm x 40 mm |
| Material | Stainless steel 316L |
| Measuring range | For formazin: 0 to 4000 FNU Display range up to 9999 FNU For sludge: 0 to 300 g/L The achievable measuring range depends very much on the media |
| Connection | G1, NPT3/4" |
| Ingress protection | IP68 (1 m / 3.3 ft) water column with 1N KCl during 60 days |
Turbidity
| Measuring Principle | Four beam alternating light |
| Application | Wastewater, process water and primary water treatment applications. Turbidity and suspended solids measurement at all stages of the wastewater treatment process and at primary water treatment applications with medium to high turbidities. |
| Installation | Insitu (immersion in process or retractable holder), extractive with sample and flow cell |
| Measuring range | For formazin: 0 to 4000 FNU Display range up to 9999 FNU For sludge: 0 to 300 g/L The achievable measuring range depends very much on the media |
| Measuring principle | Scattered light in 90°/135° and 4beam cross light |
| Design | 40 mm sensor, stainless steel |
| Material | Stainless steel 316L |
| Dimension | 194 mm x 40 mm |
| Process temperature | Process temperature: -5 to 50 °C (23 to 122 °F) Ambient temperature: -20 to 60 °C (-4 to 140 °F) |
| Connection | G1, NPT3/4" |
| Ingress protection | IP68 (1 m / 3.3 ft) water column with 1N KCl during 60 days |
The Turbimax CUS51D is an intelligent sensor for measuring suspended solids concentration that allows unattended
operation during measurement. Its unique design is highly robust, and thanks to its self-cleaning function, maintenance is required only infrequently. The sensor is selected according to different comprehensive analysis models to suit the specific application. With Memosens digital technology, the CUS51D combines maximum process and data integrity with simple operation. It is corrosion- and moisture-resistant and can be calibrated in the laboratory.
Benefits:
-
One sensor for many applications: “one device, many uses” optimizes inventory, speeds up projects and simplifies lifecycle management
-
Optimizes all types of measuring tasks: built-in analysis modules for various measuring ranges
-
Fast and simple commissioning: sensors are precalibrated and preset at the factory
-
Unattended operation: intelligent design with complex self-cleaning functions reduces maintenance
-
Perfect process suitability: fast sensor positioning with the Flexdip CYA112 and CYH112 assemblies
Application areas:
The Turbimax CUS51D measures suspended solids and turbidity, suitable for:
-
Wastewater treatment plants:
- Solids content measurement during aeration, circulation and sludge treatment
- flocculant dosing
- turbidity measurement at the outlet -
Drinking water and process water:
- solids content measurement in sludge treatment
- flocculant dosing -
Utilities:
- Solids content measurement during aeration, circulation and sludge treatment
- Flocculant dosing
Commonly used models: CUS51D-AAC1A3 and CUS51D-AAD1A3
E+H product model configurator
Please enter the product model to configure
Product comparison
Please enter the product models to be compared in the input boxes below; up to three products can be compared
Technical information
Technical data
Documents/Manuals/Software
Accessories/Spare parts
A
A
Measuring principle video
Source: public information from the Endress+Hauser website
Related Models
| Model | Name |
|---|---|
| CUS51D-10J0/0 | 浊度传感器 |
| CUS51D-AAC1A2 | 浊度传感器 |
| CUS51D-AAC1A3 | 浊度传感器 |
| CUS51D-AAC1A7 | 浊度传感器 |
| CUS51D-AAD1A3 | 浊度传感器 |
| CUS51D-AAD1B2 | 浊度传感器 |
Case Studies
市政污水处理污水处理厂 · 浊度应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对浊度的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的浊度,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 浊度应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对浊度的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的浊度,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 浊度应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对浊度的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的浊度,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 浊度应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对浊度的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的浊度,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。