Instrumentation · Engineering · Package · PLC
0755-8222 1901 info@ainstru.com

CLS19 Analog conductivity sensor

CLS19  Analog conductivity sensor

电导率传感器

Configurable Models 4 models
Conductive conductivity sensor for simple standard applications in pure and ultrapure water
Compare

Conductivity

Measuring Principle Conductive
Application Pure and ultrapure water
Characteristic 2-electrode conductivity cell for pure water applications.
Measuring range k=0,01: 0-20 µS/cm
k=0,1: 0-200 µS/cm
Measuring principle Conductive conductivity cell.
Design 2-electrode conductivity cell with coaxially arranged electrodes
Material Cell shaft: PES
Electrode: Stainless steel 1.4571
Dimension Electrode diameter: 16 mm
(0.62 inch)
Process temperature max. 60°C
max. 140°F
Process pressure max. 6 bar at 20°C
(max.87 psi at 68°F)
Temperature sensor Optional with integrated Pt100
Connection Process connection: NPT 1/2"
cable:4-pole DIN-connector with Pg9
Ingress protection IP65
Certificates, declarations and approvals Quality certification

Field of application
Condumax CLS19 measures conductivity in the low measuring ranges. It performs reliably and accurately in a wide range of applications. Designed for low maintenance and a long operating life, the sensor offers you best value for money.
Condumax CLS19 measures conductivity in pure and ultrapure water applications for the monitoring and control of:
Ion exchangers
Reverse osmosis
Cooling water
Distillation
Chip cleaning

Benefits
Reliable and accurate measuring values at low conductivities
Best price-performance ratio
Easy installation with threaded connection
Robust design for high durability
Different cell constants provide a wide measuring range

 

Conductivity:

Measuring Principle Conductive
Application Pure and ultrapure water
Characteristic 2-electrode conductivity cell for pure water applications.
Measuring range k=0,01: 0-20 µS/cm
k=0,1: 0-200 µS/cm
Measuring principle Conductive conductivity cell.
Design 2-electrode conductivity cell with coaxially arranged electrodes
Material Cell shaft: PES
Electrode: Stainless steel 1.4571
Dimension Electrode diameter: 16 mm
(0.62 inch)
Process temperature max. 60°C
max. 140°F
Process pressure max. 6 bar at 20°C
(max.87 psi at 68°F)
Temperature sensor Optional with integrated Pt100
Connection Process connection: NPT 1/2"
cable:4-pole DIN-connector with Pg9
Ingress protection IP65
Additional certifications Quality certification
Model Name
CLS19-A1A1A 电导率传感器
CLS19-A1A1D 电导率传感器
CLS19-B1A1A 电导率传感器
CLS19-B1A1D 电导率传感器
市政污水处理

市政污水处理污水处理厂 · 电导率应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 电导率应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 电导率应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 电导率应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电导率的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的电导率,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。