The Prowirl 72F is designed for the universal measurement of the volume flow of gases, steam and liquids. The proven and patented capacitive DSC sensor ensures high precision measured values even under the toughest process conditions. The Prowirl 72F offers genuine, industry-compliant two-wire technology for seamless integration into existing infrastructures and control systems.
Compare

Gas

Measuring Principle Vortex
Product headline Volume flow meter for measurement of basic liquid / gas /steam applications
Nominal diameter range DN 15...300
1/2"...12"
Max. measurement error Volume flow: +-1.0 %
Measuring range 3...19'700 m3/h
Max. process pressure PN10...250
Cl 150...1500
JIS 10...40K
Medium temperature range -200...+400°C
(-328...+752°F)
up to +450°C / 842°F on request
Degree of protection IP 67
NEMA 4x
Display/Operation Two line liquid
Crystal display
Push buttons
Quick Setup
Outputs 4...20mA
Pulse/Frequency
Status
Inputs -
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
TIIS
NEPSI/IEC on request

Liquids

Measuring Principle Vortex
Product headline Volume flow meter for measurement of basic liquid / gas /steam applications
Nominal diameter range DN 15...300
1/2"...12"
Max. measurement error +-0.75 %
Measuring range 0.16...2'360 m3/h
Max. process pressure PN10...250
Cl 150...1500
JIS 10...40K
Medium temperature range -200...+400°C
(-328...+752°F)
up to +450°C / +842°F on request
Degree of protection IP 67
NEMA 4x
Display/Operation Two line liquid
crystal display
Push buttons
Quick Setup
Outputs 4...20mA
Pulse
Status
PFM
Inputs -
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
TIIS
NEPSI/IEC on request

Steam

Measuring Principle Vortex
Product headline Volume flow meter for measurement of basic liquid / gas /steam applications
Nominal diameter range DN 15...300
1/2"...12"
Max. measurement error Volume flow: +-1.0 %
Measuring range 3...19'700 m3/h
Max. process pressure PN10...250
Cl 150...1500
JIS 10...40K
Medium temperature range -200...+400°C
(-328...+752°F)
up to +450°C / 842°F on request
Degree of protection IP 67
NEMA 4x
Display/Operation Two line liquid
Crystal display
Push buttons
Quick Setup
Outputs 4...20mA
Pulse
Status
PFM
Inputs -
Digital communication HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals ATEX
FM
CSA
TIIS
NEPSI/IEC on request

Universal volumetric flow measurement of gases, steam and liquids. Thanks to the built-in temperature measurement and the reading of an external pressure value (Prowirl 73), the mass flow of steam, water (in accordance with the IAPWS-IF97 ASME standard), natural gas (in accordance with the AGA NX-19 / AGA8-DC92 detailed method / AGA8 Gross Method 1 / SGERG-88 standard), compressed air, other gases and liquids can be calculated.

Benefits
The Prowirl sensor family has passed more than 200,000 tests and verifications and offers the following advantages:
• High vibration resistance, resistance to temperature shocks, suitable for contaminated fluids, resistance to water hammer
• Maintenance-free, no moving parts, no zero-point drift (“lifetime” calibration)
• Software-based initial setup saves time and operating costs
Extended applications:
• A single instrument measures the mass flow of saturated steam or liquids
• Built-in flow computer calculates the mass flow based on the measured volumetric flow and temperature values
• External pressure input for measuring superheated steam and gases
• External temperature input for heat exchange measurement


Application
• Fluid temperature range: –200 ... +400 °C (–328 ... +752 °F)
• Pressure ratings up to PN 250 / Class 1500 
• The sensor features an integrated reducer, with selectable one-stage reduction (type R) or two-stage reduction (type S)
• Optional dual-sensor flowmeter (Dualsens type) for redundant measurement, with two sensors and two sets of electronics
Hazardous area approvals:
•ATEX, FM, CSA, TIIS, NEPSI, IEC
•HART, PROFIBUS PA, FOUNDATION Fieldbus (FF)
• Pressure Equipment Directive (PED), SIL-2 safety

市政污水处理

市政污水处理污水处理厂 · 涡街流量计应用案例

项目背景

市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对涡街流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的涡街流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应市政污水处理复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料

食品饮料食品生产线 · 涡街流量计应用案例

项目背景

食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对涡街流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的涡街流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应食品饮料复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药

化工制药反应釜与储罐 · 涡街流量计应用案例

项目背景

化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对涡街流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的涡街流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应化工制药复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源

电力能源电厂锅炉与汽机 · 涡街流量计应用案例

项目背景

电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对涡街流量计的稳定性与测量精度提出了更高要求。

解决方案

阿仪科技技术团队结合现场工况,为客户选配了适配的涡街流量计,并完成选型、安装、调试与整定的一站式交付。

实施效果

  • 测量精度与响应速度显著提升,数据稳定可靠;
  • 仪表适应电力能源复杂工况,维护量大幅降低;
  • 助力客户实现连续在线监测与降本增效,获得客户高度认可。