有源安全栅
Technical Data
ComparePower supplies & barrier
| Measuring Principle | Active barrier |
| Measuring principle | Active barrier |
| Function | 1-channel 2-channel Signal doubler |
| Loop power supply | 17,5 V ±1 V bei 20 mA open circuit voltage: 24,5 V ±5 % |
| Power Supply | 24 V DC |
| Input | 0/4…20 mA / HART feeding/not feeding |
| Output | 0/4…20 mA / HART active/passive |
| Certificates | ATEX Ex tc CSA C/US AIS JPN [Ex ia Ga], [Ex ia Da], Ex ec KC [Ex ia Ga], [Ex ia Da], Ex ec INMETRO [Ex ia Ga], [Ex ia Da], Ex ec NEPSI [Ex ia Ga], [Ex ia Da], Ex ec UK Ex tc, [Ex ia Ga], [Ex ia Da], Ex ec ATEX IECEx [Ex ia Ga], [Ex ia Da], Ex ec UL C/US DNV EAC [Ex ia Ga] IIC, [Ex ia Da] IIIC, Ex ec IIC Gc |
| SIL | SIL 2 SC 3 |
| Operation | HART |
The RN22 active barrier is available as a single-channel or dual-channel version, powers instrument loops for analog communication and safety instrumented systems up to functional safety level SIL 2 (SC 3). With intrinsically safe transparent HART® transmission mode, the interface reliably establishes a link between field instruments and the process control level. It is used in hazardous areas as an interface for two-wire/four-wire devices, provides a second isolated signal output and complies with NAMUR NE 175. It opens a second channel for process optimization without affecting conventional automation systems.
Advantages
Intrinsically safe interface module for use in safety instrumented systems up to functional safety level SIL 2 (SC 3), complying with IEC 61508
Fast and convenient wiring using screw terminals or push-in terminals, or power supply via the power rail T-connector
HART® interface on the front panel for convenient operation
Small, compact housing: optional dual-channel version with a width of only 12.5 mm (0.49 in), making efficient use of the space inside the control cabinet
Field of application
Single-channel or dual-channel active barrier, power supply or signal multiplier
Isolated transmission of 0/4 ... 20 mA analog signals (NAMUR NE 43)
Intrinsically safe certification for use in Zone 2 explosion-protected areas
Bidirectional HART® communication (transparent transmission mode)
Connection of two-wire and four-wire devices in hazardous areas
Ambient temperature range: -40 … 60 °C (-40 … 140 °F)
E+H product configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products you wish to compare in the fields below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserpublic information from the website
Related Models
| Model | Name |
|---|---|
| RN22-8L2BLAZ1 | 有源安全栅 |
Case Studies
市政污水处理污水处理厂 · 电源和安全栅应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对电源和安全栅的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电源和安全栅,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 电源和安全栅应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对电源和安全栅的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电源和安全栅,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 电源和安全栅应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对电源和安全栅的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电源和安全栅,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 电源和安全栅应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对电源和安全栅的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的电源和安全栅,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。