浸入式支架
Technical Data
CompareAnalyser
| Measuring Principle | UV photometric |
| Characteristic | Simple and easy installation Universal and flexible |
| Design | Versions in stainless steel or PVC |
| Process temperature | 0 to 60 °C (32 to 140 °F) |
| Application | Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels |
Conductivity
| Measuring Principle | Conductive |
| Application | Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels |
| Installation | CYA112 is a modular assembly system for sensors in open basins, channels and tanks |
| Characteristic | Simple and easy installation Universal and flexible |
| Design | Versions in stainless steel or PVC |
| Material | Immersion pipe, connection angle, welded threads: stainless steel 1.4404 Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF O-rings: EPDM |
| Dimension | Tauchrohr Durchmesser: 40 mm (1.57 Zoll) Länge: 600, 1200, 1800 und 2400 mm (23.6, 47.2, 70.9 und 94.5 Zoll) |
| Process temperature | 0 ... 60 °C (32 ... 140 °F) |
Disinfection
| Measuring Principle | Total chlorine |
| Application | Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels |
| Characteristic | Simple and easy installation Universal and flexible |
| Design | Versions in stainless steel or PVC |
| Material | Immersion pipe, connection angle, welded threads: stainless steel 1.4404 Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF O-rings: EPDM |
| Dimension | Immersion pipe diameter: 40 mm (1.57 inch) Length: 600, 1200, 1800 and 2400 mm (23.6, 47.2, 70.9 and 94.5 inch) |
| Process temperature | 0 to 60 °C (32 to 140 °F) |
ORP / Redox
| Measuring Principle | Sensor ORP / Redox |
| Application | Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels |
| Installation | CYA112 is a modular assembly system for sensors in open basins, channels and tanks |
| Characteristic | Simple and easy installation Universal and flexible |
| Design | Versions in stainless steel or PVC |
| Material | Immersion pipe, connection angle, welded threads: stainless steel 1.4404 Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF O-rings: EPDM |
| Dimension | Immersion pipe diameter: 40 mm (1.57 inch) Length: 600, 1200, 1800 and 2400 mm (23.6, 47.2, 70.9 and 94.5 inch) |
| Process temperature | 0 to 60 °C (32 to 140 °F) |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels |
| Installation | CYA112 is a modular assembly system for sensors in open basins, channels and tanks |
| Characteristic | Simple and easy installation Universal and flexible |
| Design | Versions in stainless steel or PVC |
| Material | Immersion pipe, connection angle, welded threads: stainless steel 1.4404 Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF O-rings: EPDM |
| Dimension | Immersion pipe diameter: 40 mm (1.57 inch) Length: 600, 1200, 1800 and 2400 mm (23.6, 47.2, 70.9 and 94.5 inch) |
| Process temperature | 0 to 60 °C (32 to 140 °F) |
Turbidity
| Measuring Principle | Single beam scattered light |
| Application | Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels |
| Installation | CYA112 is a modular assembly system for sensors in open basins, channels and tanks |
| Characteristic | Simple and easy installation Universal and flexible |
| Design | Versions in stainless steel or PVC |
| Material | Immersion pipe, connection angle, welded threads: stainless steel 1.4404 Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF O-rings: EPDM |
| Dimension | Immersion pipe diameter: 40 mm (1.57 inch) Length: 600, 1200, 1800 and 2400 mm (23.6, 47.2, 70.9 and 94.5 inch) |
| Process temperature | 0 to 60 °C (32 to 140 °F) |
pH
| Measuring Principle | Potentiometric |
| Application | Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels |
| Installation | CYA112 is a modular assembly system for sensors in open basins, channels and tanks |
| Characteristic | Simple and easy installation Universal and flexible |
| Design | Versions in stainless steel or PVC |
| Material | Immersion pipe, connection angle, welded threads: stainless steel 1.4404 Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF O-rings: EPDM |
| Dimension | Immersion pipe diameter: 40 mm (1.57 inch) Length: 600, 1200, 1800 and 2400 mm (23.6, 47.2, 70.9 and 94.5 inch) |
| Process temperature | 0 to 60 °C (32 to 140 °F) |
The Flexdip CYA112 is a modular holder for installing sensors in open basins, channels and tanks. It allows the installation of almost all types of sensors, including chain, fixed and freely swinging versions. Faster and safer installation is possible for Memosens and fixed cable sensors. The holder offers excellent flexibility and enables cost-effective, optimum configuration of the entire measuring point.
Benefits
Modular design for optimum configuration of each measuring point
Non-contact plug-in Memosens sensors for fast installation and replacement
No tangling when installing sensors with integrated cables
Simple installation and maintenance
Robust design: suitable for process pressures up to 6 bar (87 psi)
Applications
The Flexdip CYH112 holder is suitable for measurements in open basins, channels and tanks:
Wastewater treatment plants
Waterworks
Utilities
With the Flexdip CYA112 holder, a perfect measuring system is created and sensors can be easily isolated.
The Flexdip measuring system can measure the following parameters:
pH/ORP
Conductivity
Dissolved oxygen
Turbidity
Sludge level
Disinfection
UV photometry
Nutrients
E+H Product Model Configuration Tool
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the fields below; up to three products can be compared
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source: Endress+Hauserpublic information from the website
Related Models
| Model | Name |
|---|---|
| CYA112-AA11C1AA+IA | 浸入式支架 |
| CYA112-AA11C1AB+IA | 浸入式支架 |
| CYA112-AA11C1AE+IA | 浸入式支架 |
Case Studies
市政污水处理污水处理厂 · 支架应用案例
项目背景
市政污水处理客户在污水处理厂环节,长期面临「出水水质监测精度不足、仪表易受污染导致数据漂移,影响达标排放」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应市政污水处理复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
食品饮料食品生产线 · 支架应用案例
项目背景
食品饮料客户在食品生产线环节,长期面临「卫生级测量要求高,在线仪表需耐 CIP/SIP 清洗且精度稳定」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应食品饮料复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
化工制药反应釜与储罐 · 支架应用案例
项目背景
化工制药客户在反应釜与储罐环节,长期面临「介质腐蚀性强、工况复杂,仪表需耐腐蚀且防爆」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应化工制药复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。
电力能源电厂锅炉与汽机 · 支架应用案例
项目背景
电力能源客户在电厂锅炉与汽机环节,长期面临「高温高压工况下测量不稳定,维护停机成本高」的困扰,对支架的稳定性与测量精度提出了更高要求。
解决方案
阿仪科技技术团队结合现场工况,为客户选配了适配的支架,并完成选型、安装、调试与整定的一站式交付。
实施效果
- 测量精度与响应速度显著提升,数据稳定可靠;
- 仪表适应电力能源复杂工况,维护量大幅降低;
- 助力客户实现连续在线监测与降本增效,获得客户高度认可。