| Nr |
Order Number |
Specifications |
|
|
Please return the unit to PC for repair |
| 1 |
71076316 |
power adapter 12VDC/2500mA LEMO interface |
| 2 |
71094796 |
Terminal |
|
50091703 |
Normal Temperature Sound Velocity Sensor
Sound velocity measuring sensors
Prosonic Flow 93; sensor pair
measurement of sound velocity in
fluid.
|
|
50091704 |
high temperature sound velocity sensor
Sound velocity measuring sensors
Prosonic Flow 93; sensor pair
measurement of sound velocity in
fluid.
|
|
71112217 |
sensor DDU 20
Wall thickness measuring sensor
Prosonic Flow 93T; sensor for measuring
pipe wall thickness.
|
|
|
Overview auxiliary equipment
see spare part picture |
|
93TA1- |
Portable ultrasonic flowmeter 93T
Battery operated Ultrasonic Flowmeter
set incl. datalog function
time stamp, 1GB USB Stick
carry case, charger, battery pack
acoustic couple medium
8 hours continious operation.
| P Sensor set DN15-DN65 1/2-2 1/2"/6MHz: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
not selected |
| B |
-40...100oC/-40...212oF installation set |
| C |
-40...150oC/-40...302oF installation set |
| P Sensor set DN50-DN300 2"-12"/2MHz: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
not selected |
| B |
-40...80oC/-40...176oF installation set |
| C |
0...170oC/32...338oF installation set |
| P Sensor Set DN100-DN4000 4"-160"/1MHz: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
not selected |
| B |
-40...80oC/-40...176oF installation set |
| Sensor Cable: |
| 9 |
Special version, TSP-no. to be spec. |
| E |
5m/15ft, PTFE, -40...170 oC/-40...338oF |
| F |
10m/30ft, PTFE, -40...170 oC/-40...338oF |
| Approval: |
| A |
Non-hazardous area |
| E |
Non-hazardous area EAC marking |
| Operation language: |
| A |
WEA = DE EN FR IT ES PT NL |
| C |
SEA = JA ID EN |
| E |
EES = SV FI NO RU PL CS EN |
| G |
CN = ZH EN |
| >>Sound velocity sensor set: |
| D1 |
DN50-DN3000 2 "-180" |
| >>Wall thickness sensor: |
| E2 |
>DN15 1/2" |
| >>Additional Test, certificate: |
| F1 |
Verification DN50 2", sensor DN15-DN65 1/2"-2 1/2" |
| F2 |
Verification DN100 4", sensor DN50-DN300 2"-12" |
| F3 |
Verification DN100 4", sensor DN100- DN4000 4"-160" |
| >>Accessory: |
| P1 |
Cable 93T - FXA193 |
| P2 |
Car charging adapter cable |
| P3 |
Rechargable battery pack 93T, 4000 mAh |
| P4 |
Installation set <4000 160" <80°C |
| P5 |
Cable 93T - FXA291 |
|
|
DK9PT- |
Ultrasonic 93T, flow meter sensor
For use with Prosonic Flow 93T
portable transmitter
| P sensor: |
| 1 |
DN15-DN65, -40...100oC, 6.0MHz 1/2... 2 1/2 ", -40... 212oF |
| 2 |
DN15-DN65, -40...150oC, 6.0MHz 1/2... 2 1/2 ", -40... 302oF |
| 9 |
special version, TSP-no. to be spec. |
| A |
DN100-DN4000, -40...80oC, 1.0MHz 4... 169 ", -40... 176oF |
| B |
DN50-DN300, -40...80oC, 2.0MHz 2... 12 ", 40... 176oF |
| F |
DN50-DN300, 0...170oC, 2.0MHz 2... 12 ", 40... 176oF |
| Approval: |
| A |
non-hazardous area |
|
|
DK9SS- |
Ultrasonic 91/93/93T, sensor cable
| Transmitter: |
| C |
Prosonic Flow 93T |
| Sensor Type: |
| E |
93T, P sensor |
| Sensor cable: |
| E |
5m/15ft, PTFE, -40...170oC/-40...338oF |
| F |
10m/30ft, PTFE, -40...170oC/-40...338oF |
|
|
DK9SH- |
W/P Type Sensor Block Assembly DK9SH
| Sensor holder: |
| 2 |
Clamp On, portable DN15-DN65 1/2"-2 1/2" |
| 9 |
Special version, TSP-no. to be spec. |
| B |
Clamp On, detachable retaining nut W/P sensor DN50-DN4000 2"-160" |
|
|
DK9ZT- |
Portable ultrasonic 93T accessories (including battery pack, mounting components, etc.)
| Accessorie: |
| 1 |
Cable 93T - FXA193 |
| 2 |
Car charging adapter cable |
| 3 |
Rechargeable battery pack 93T, 4000 mAh |
| 4 |
Installation set |
| 5 |
Installation set |
| 6 |
Sensor connector, adapter set W/P sensor |
| 7 |
USB Stick, 1GB |
| 8 |
Cable 93T - FXA291 |
| A |
Cable adapter, 93T to 93P DN15-65 Sensor |
| B |
Installation set |
| C |
Carrying bag |
|
|
FXA193- |
communication interface FXA193
The service interface connects
service port of Proline and ToF devices
with the serial interface RS 232C
(9 pin.) of a personal computer.
Contents of delivery:
-Serviceinterface with RS 232C
connection cable (9 pin.)
-FXA "USB" cable, the additional
power supply for FXA193 from USB-port
of the PC.
-Service Softw.ToF Tool-Fieldtool
Package
| Approval: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
For use in non-hazardous area |
| B |
ATEX II (1) GD |
| C |
CSA/FM Class I Div. 1 |
| D |
ATEX, CSA, FM |
| Connection Cable: |
| 9 |
Special version, TSP-no. to be spec. |
| A |
Proline device |
| B |
ToF device |
| E |
Proline and ToF device |
| F |
Ex two-wire device |
| G |
Proline device and Ex two-wire device |
| H |
Proline, ToF and Ex two-wire device |
| X |
Without connection cable |
|