106663 CN 800 DIN
Combined Cyanide selective electrode, with 3.3 ft (1 m) cable, DIN plug, 0.2 to 260 mg/l requires ELY/BR/503 reference electrolyte, ionic strength adapter MZ/NH3/CN. Standard solutions have to be prepared freshly. Delivery contains electrolyte!
组合式氰化物选择性电极,带3.3英尺(1米)电缆,DIN插头,0.2至260毫克/升,需要ELY/BR/503参考电解质,离子强度适配器MZ/NH3/CN。标准溶液必须新鲜制备。交付包含电解液!
组合式氰化物选择性电极,带3.3英尺(1米)电缆,DIN插头,0.2至260毫克/升,需要ELY/BR/503参考电解质,离子强度适配器MZ/NH3/CN。标准溶液必须新鲜制备。交付包含电解液!
售价:
¥
0.00
原价:
¥0.00
ꄑ0
-
Ion-selective electrodes
Potassium, Fluoride, Aluminium, Phosphate, Lithium, Ammonium, Copper, Cyanide, Chloride, Sodium, Calcium, Magensium, Silver, Nitrate, Bromide
Ion-selective and gas-sensitive electrodes are used for measuring the dissolved concentration of specific ions or gases in water. Similar to the pH electrode, the membrane interacts with the dissolved ions and delivers a concentration-dependent voltage signal that is converted to the corresponding measurement result.
Highlights:- Space-saving through integrated reference electrode
-
broad selection of applications including ammonium measurement
-
Slim and space-saving design with 12 mm shaft diameter
Variants Art.-Nr. Name Description Connection 106395 NH 500/2 Ammonium-selective electrode S7-Plug head, without cable 106649 Na 800/S7 Sodium-selective electrode S7-Plug head, without cable 106651 Ag/S 800 DIN Silver-/Sulphide-selective electrode 1 m DIN cable 106653 Br 800 DIN Bromide-selective electrode 1 m DIN cable 106655 Ca 800 DIN Calcium-/Magnesium-selective electrode 1 m DIN cable 106656 Ca 800/AT Exchange head for Ca 800 - 106661 Cl 800 DIN Chloride-selective electrode 1 m DIN cable 106663 CN 800 DIN Cyanide-selective electrode 1 m DIN cable 106665 Cu 800 DIN Copper-/Nickel-selective electrode 1 m DIN cable 106666 F 800 BNC Fluoride-/Aluminium-/
Phosphate-/Lithium-selective electrode1 m BNC cable 106667 F 800 DIN Fluoride-/Aluminium-/
Phosphate-/Lithium-selective electrode1 m DIN cable 106671 K 800 DIN Potassium-selective electrode 1 m DIN cable 106672 K 800/AT Exchange head for K 800 - 106675 NO 800 DIN Nitrate-selective electrode 1 m DIN cable -
Electrode NH 500/2 Na 800/S7 Ag/S 800 DIN Br 800 DIN Art.-No. 106395 106649 106651 106653 Ions Ammonium Sodium Silver-/Sulphide Bromide Measuring range 10-6 ... 5 · 10-2 mol/l NH4+
0,02 ... 900 mg/l NH4+10-6 ... 1 mol/l Na+
0,01...23000 mg/l Na+Ag: 0,01 ... 108.000 mg/l
Sulfid: 0,003 bis 32.000 mg/l0,4 ... 79000 mg/l Br- Reference electrolyte - 3 mol/l KCl - - Diaphragm - Platin - - pH range 8 ... 11 2 ... 12 1 ... 12 Temperature range 0 ... 50 °C -10 ... +80 °C 0 ... 80 °C 0 ... 80 °C Membrane resistance < 500 MΩ < 1 MΩ < 0,1 MΩ Shaft length 120 mm 120 mm 120 mm 120 mm Shaft diameter 12 mm 12 mm 12 mm 12 mm Immersion depth min. 5 mm
max. 50 mmmin. 20 mm
max. 100 mmNeeds: Ionic strength-adjusting
solution MZ/NH3/CN,
Standard solution ES/NH4Ionic strength-adjusting
solution ISA/Na,
Standard solution ES/Na,
Cable AS/DIN or AS/BNCBridge electrolyte ELY/BR/503,
Ionic strength-adjusting solution ISA/FK (Ag-Ionen) or according
to the operating
instructions for sulphide
measurementBridge electrolyte ELY/BR/503,
Ionic strength-adjusting solution ISA/FK,
Standard solution ES/BrAddit.
scope of delivery3 exchange heads, 50 ml electrolyte solution - - Electrolyte Connection S7-plug head, without cable S7-plug head, without cable 1 m DIN cable 1 m DIN cable Elektrode Ca 800 DIN Cl 800 DIN CN 800 DIN Cu 800 DIN Art.-No. 106655 106661 106663 106665 Ions Calcium Chloride Cyanide Copper/Nickel Measuring range 0,02 ... 40.000 mg/l Ca2+ 2 ... 35.000 mg/l Cl- 0,2 ... 260 mg/l CN- (empfohlen 0,2 ... 25 mg/l CN- )
8 x 10-6 ... 1 x 10-2 mol/l CN-
(empfohlen 8 x 10-6 ... 1 x 10-3 mol/l CN- )6 x 10-4 ... 6.350 mg/l Cu2+ Reference electrolyte - - - - Diaphragm - - - - pH range 2,5 ... 11 2 ... 12 0 ... 14 2 ... 6 Temperature range 0 ... 40 °C 0 ... 80 °C 0 ... 80 °C 0 ... 80 °C Membrane resistance 1 bis 4 MΩ < 1 MΩ < 30 MΩ < 1 MΩ Shaft length 120 mm 120 mm 120 mm 120 mm Shaft diameter 12 mm 12 mm 12 mm 12 mm Immersion depth Needs: Bridge electrolyte ELY/BR/503,
Ionic strength-adjusting solution ISA/Ca,
Standard solution ES/CaBridge electrolyte ELY/BR/503,
Ionic strength-adjusting solution ISA/FK,
Standard solution ES/ClBridge electrolyte ELY/BR/503,
Ionic strength-adjusting solution MZ/NH3/CNBridge electrolyte ELY/BR/503,
Ionic strength-adjusting solution ISA/FK
Standard solution ES/CuAddit.
scope of deliveryElectrolyte and exchange heads Electrolyte Electrolyte Electrolyte Connection 1 m DIN cable 1 m DIN cable 1 m DIN cable 1 m DIN cable Elektrode F 800 BNC F 800 DIN K 800 DIN NO 800 DIN Art.-No. 106666 106667 106671 106675 Ions Fluoride/Aluminium/
Phosphate/LithiumPotassium Nitrate Measuring range 0,02 mg/l F- (10-6 mol/l) bis Sättigung 0,04 ... 39.000 mg/l K+ 0,4 ... 62.000 mg/l NO3- Reference electrolyte - - - Diaphragm - - - pH range 5 ... 7 2 ... 12 2,5 ... 11 Temperature range 0 ... 80 °C 0 ... 40 °C 0 ... 40 °C Membrane resistance 0,15 ... 0,2 MΩ < 50 MΩ 1 bis 5 MΩ Shaft length 120 mm 120 mm 120 mm Shaft diameter 12 mm 12 mm 12 mm Immersion depth Needs: Bridge electrolyte ELY/BR/503,
Ionic strength-adjusting solution TISAB,
Standard solution ES/FBridge electrolyte ELY/BR/503/K,
Ionic strength-adjusting solution ISA/K,
Standard solution ES/KBridge electrolyte ELY/BR/503/N,
Ionic strength-adjusting solution TISAB/NO3,
Standard solution ES/NO3Addit.
scope of deliveryElectrolyte and exchange heads Electrolyte and exchange heads Electrolyte and exchange heads Connection 1 m BNC cable 1 m DIN cable 1 m DIN cable 1 m DIN cable